Hey there! I’m a supplier of non – clogging sewage pumps, and I often get asked this question: "Does a non – clogging sewage pump need a check valve?" Well, let’s dig into this topic and break it down to see what’s what. Non-clogging Sewage Pump

First off, let’s talk about what a non – clogging sewage pump is. These pumps are a game – changer in dealing with sewage and wastewater. You see, normal pumps can get easily clogged with all the stuff that goes down our drains, like hair, toilet paper, and small solid particles. But non – clogging sewage pumps are designed to handle these solids without getting blocked up. They’ve got special impellers and designs that allow the solids to pass through smoothly.
Now, what’s a check valve? A check valve is a simple but super important device. It’s like a one – way door for fluid. It allows the fluid to flow in one direction and stops it from flowing back. When the pump is working, the fluid (sewage in this case) can push through the check valve and move forward. But when the pump stops, the check valve closes, preventing the sewage from flowing back into the pump.
So, does a non – clogging sewage pump really need a check valve? Well, there are a few factors to consider.
Advantages of Using a Check Valve with a Non – Clogging Sewage Pump
1. Prevent Backflow
One of the biggest reasons to use a check valve is to prevent backflow. When the pump shuts off, without a check valve, the sewage that has been pumped up can flow back down into the sump pit or the source. This can cause a whole bunch of problems. For example, if the pump has to start up again, it will have to pump the same sewage all over again, which wastes energy. Also, the back – flowing sewage can carry debris that might clog the pump, even if it’s a non – clogging one. Over time, this repeated back – and – forth movement of sewage can wear out the pump components faster.
2. Maintain Prime
A check valve helps the pump maintain its prime. Prime is basically the presence of fluid in the pump so that it can start working effectively. When the check valve keeps the sewage from flowing back, the pump stays filled with fluid. This means that when you need to start the pump again, it doesn’t have to go through the process of re – priming, which can be time – consuming and sometimes difficult. It can just kick into action right away.
3. Protect the Pump
Backflow can cause water hammer. Water hammer is a pressure surge or wave that occurs when the flow of fluid in a pipe is suddenly stopped or changed direction. This can create a loud banging noise and put a lot of stress on the pump and the pipes. A check valve can prevent water hammer by gradually closing and stopping the backflow, protecting the pump from this potentially damaging force.
Situations Where a Check Valve Might Not Be Necessary
1. Short Discharge Lines
If the discharge line (the pipe that the sewage is pumped through) is really short, say less than 10 feet, the risk of significant backflow is relatively low. In this case, the force of gravity pulling the sewage back might not be strong enough to cause major problems. So, in some very specific situations with short discharge lines, you might be able to get away without a check valve.
2. Low – Pressure Systems
In low – pressure sewage systems where the pressure differences are minimal, the backflow might not be a huge issue. If the pump is only pumping the sewage a short distance and at a low pressure, the chances of the sewage flowing back and causing damage are reduced.
But even in these situations, it’s still a good idea to think twice before skipping the check valve. The potential benefits of having a check valve usually outweigh the small savings or convenience of not having one.
Types of Check Valves for Non – Clogging Sewage Pumps
There are a few different types of check valves that can be used with non – clogging sewage pumps.
1. Swing Check Valves
Swing check valves are one of the most common types. They have a hinged disc that swings open when the fluid is flowing in the right direction and swings shut when the flow stops or reverses. They’re relatively simple and inexpensive. However, they can be a bit slow to close, which might not be ideal in situations where you need to prevent water hammer quickly.
2. Ball Check Valves
Ball check valves use a ball to control the flow. When the fluid is flowing forward, the ball is pushed out of the way. When the flow reverses, the ball is pushed back into place to block the flow. They’re generally faster to close than swing check valves, which makes them better at preventing water hammer. But they can be a bit more expensive.
3. Diaphragm Check Valves
Diaphragm check valves use a flexible diaphragm to control the flow. They’re very reliable and can handle a wide range of pressures and fluids. They’re also good at preventing backflow and water hammer. However, they can be more complex and costly than the other types.
Installation and Maintenance
Installing a check valve for your non – clogging sewage pump is not too difficult, but there are a few things to keep in mind.
First, make sure you install the check valve in the right direction. There’s usually an arrow on the valve that shows the correct flow direction. If you install it backwards, it won’t work properly.
Second, the check valve should be installed as close to the pump as possible. This helps to minimize the amount of sewage that can flow back into the pump.
As for maintenance, you should check the check valve regularly. Look for any signs of wear, damage, or clogging. If the valve is clogged, it might not close properly, which can lead to backflow. You can clean the valve if it’s clogged, but if it’s damaged, you’ll probably need to replace it.
In conclusion, while there are some situations where a non – clogging sewage pump might not strictly need a check valve, in most cases, it’s a really good idea to use one. A check valve can prevent backflow, maintain the pump’s prime, and protect the pump from water hammer. It’s a small investment that can save you a lot of headaches in the long run.

If you’re in the market for a non – clogging sewage pump or need advice on whether you need a check valve for your specific situation, don’t hesitate to reach out. We’re here to help you make the best decision for your sewage pumping needs. Let’s have a chat and see how we can work together to get your sewage system running smoothly.
Sewage Pump References
- "Pump Handbook" by Igor J. Karassik, Joseph P. Messina, Paul Cooper, and Charles C. Heald
- "Sewage Treatment and Disposal" publications by various environmental engineering institutions